摘要: 为缩短系统级BIT的平均故障隔离时间,吸取直接熵法的基本思想,运用信息流模型 和信息理论,提出系统级故障隔离的间接熵法,并讨论了工程中应用间接熵法时所需考虑的相关 问题.实验验证和理论分析表明,该方法弥补了直接熵法构造故障隔离策略时需进行人工干预、计 算复杂性高的不足;在不等故障概率的假设条件下,平均故障隔离时间比直接熵法减少约38%.Abstract: In order to shorten the mean fault isolation time (MFIT) of system-level BIT, an entropy-indirected algorithm for system-level fault isolation is developed based on the main idea of enl ropy-directed algorithm by using the information flow model and information theory.The related problems are also discussed in engineering application. The entropy-directed algorithm needs manual intervention to construct fault isolation strategy,and it is ofεhigh computation complexity.Theoretical analysis and experimental results illustrate that the entropy indirected algorithm remedies such deficiency. The MFIT of the strategy by this algorithm is about 38% less than that by the entropy- directed algorithm under the assumption of unequal fault rate.
-
Key words:
- System-level BIT /
- fault isolation strategy /
- information /
- entropy
计量
- 文章访问数: 2280
- HTML全文浏览量: 102
- PDF下载量: 952
- 被引次数: 0